Q: I've just ordered a Tecpel 8020 digital
multimeter with capacitance. I would also like to get a high voltage probe that will
function with it, however most of the high voltage probes I find simply state that they
will work with any multimeter with an input impedance of 10Mohms, your specification of
the 8020 state that it has an input impedance of 20Mohms - how will this affect my finding
a HV probe for this meter? Please help.
A: In general, the meter's input
impedance should always be much, much higher than the source impedance of the device under
test. When evaluating input impedance of a multimeter, therefore, the higher the
value the better. A meter with an input impedance spec of 20Mohms will have less
"loading error" on the measurement than a meter with a spec of 10Mohms,
therefore produce a more repeatable result.
The 10Mohm spec of your high voltage probe refers to the MINIMUM requirements of the meter
that you use it with. If you tried to use it with a meter that had a 1Mohm input
impedance, you would get very inaccurate readings.
Bottom line - go ahead and use the high voltage probe you have in mind...it will work fine
with the Tecpel 8020.
Q: Can you recommend a good on-line
guide for using a DMM, especially for around the home applications?
A: A good basic guide for the
home can be found at HomeCentral.com. Click the
following link:
http://www.sierra.com/sierrahome/homedesign/howto/record/0,1179,558,00.html
In addition, the following sites have good info on basic theory and use of
multimeters. The principles described can easily be applied to in-home
applications:
www.boatsafe.com/nauticalknowhow/electricity2.htm
www.users.dircon.co.uk/~doctron/meter.htm
Q: Is it possible to use a DMM to
measure the total load being drawn on a given circuit? For example, can you use the
meter on a normal 110VAC plug or lighting fixture to see how many amps are being pulled by
other devices on the circuit? The problem is that I share circuits with other offices and
would like to know how many amps I have left to play with - I don't want my computer on a
circuit that has a fridge or air conditioner etc on it.
A: All 120V receptacles on a circuit are
connected in parallel, therefore all will read 120V. The current draw of each
"leg" of the circuit will be different, depending what is connected (i.e. the
refrigerator, computer, etc.) Total current draw of a given circuit is is the sum of
each "leg" , and is limited by the circuit breaker in the electrical box.
There are a couple of ways you can determine how many amps are left:
1.) Determine which receptacles are on your circuit, and measure the current draw of
each appliance, light, or device that is plugged-in. Sum the total, and compare to
the rating of the circuit breaker that is used (in the breaker box). This is a very
easy measurement to make with a Clamp-Style DMM.
2.) Determine which circuit breaker is used for your office, and measure the current
draw at the breaker. Measuring here will give you the total current draw of the
circuit (assuming all devices are plugged-in and operating). Again, a Clamp-Style
DMM will make this job easy.
In each of the above cases, subtract this total current draw from the circuit breaker
rating to determine how much "capacity" is left in your circuit.
We have a variety of Clamp Meters available that can do this job, with prices starting at
around $75. Clamp meters are the most versatile meters for the home, as they can
easily measure amps, volts, and resistance.
|